Welcome to Sino-Hero(Shenzhen)Bio-Medical Electronics Co.,Ltd
mTouch6
Catalog Download
Product Introduction

Neonatal Monitor


Features:

●Specialty model distinctly for NEONATE monitoring
●Unique ECG, NIBP and Masimo Sp02 technology devoting on neonate care
●Ultra bright and vivid 8.4" Full Touch Screen
●Ultimate compact and light design
●Various interfaces with maximum 96 hours trends review
●Built-in rechargeable Li-ion battery ensuring 4 hours continuous operation

Technical Specification

Size and Weight
- Product size: 24.9x22.3x10.7cm
- Packing size: 38x32x29cm
- Net weight: 3.5kg
- Gross weight: 7kg

Operation Environment
- Power : AC100-250V, 50/60Hz
- Temperature: 0-40℃
- Humidity: 15-85%

Patient Range
- Neonate

Performance Specifications
- Display: 8.4inch color TFT touch screen (diagonal)
- Resolution: 800×600
- Sweep Speed: 12.5mm/s, 25mm/s, 50mm/s
- Indicator: Power indicator light
Battery indicator light
Alarm indicator light
QRS beep and alarm sound
- Inter face: Parameter cable inter face
AC Power input socket
Network inter face
SD card socket
- Battery: Lithium-ion battery / Rechargeable
4 hours for continuous working
- Trend time: 96 hours
- Alarm: User-adjustable High and Low
limits alarm events recallable
audible and visual alarm
- Networking: Connected to central monitoring system
- Recorder: Built-in, thermal array,
2 traces, paper width: 50mm
- Recorder mode: manual, on alarm,
time-defined
- Print speed: 12.5mm/s, 25mm/s, 50mm/s

ECG
- Lead ion: 3-lead
RESP
- Method: Thoracic impedance
- RR measurement range: 7-150rpm
- Resolution: ±1rpm
- Accuracy: ±1rpm

Masimo-SpO2
- Measurement Range:0% to 100%
- Resolution:1%
- Accuracy: 70% to 100%:±2%(adult/pediatric,non-motion conditions)
70% to 100%:±2%(adult/pediatric,non-motion conditions)
70% to 100%:±3%(neonate,non-motion conditions)
70% to 100%:±3%(motion conditions)
0% to 69%, unspecified

PR
- Measurement Range:25bpm to 240bpm
- Accuracy: ±3bpm(non-motion conditions)
±5bpm(motion conditions)
- Resolution:1bpm

NIBP
- Measurement method: Automatic vibration,
- NIBP cuff: four sizes of cuffs
- Measurement types: Systolic, Diastolic, Mean
- Work mode: Manual / Automatic
- Auto measurement time: Adjustable 1 min-480min
- Measurement unit: mmHg / Kpa able
- Measurement range:
Pediatric Mode:
Systolic pressure: 40-200mmHg
Diastolic pressure: 20-165mmHg
Mean pressure: 10-150mmHg
Neonatal Mode:
Systolic pressure: 40-150mmHg
Diastolic pressure: 10-100mmHg
Mean pressure: 20-110mmHg
- Alarm type: Systolic pressure, Diastolic
Pressure, Mean pressure
- Accuracy: ±5mmHg
- NIBP pressure range: 0-300mmHg
- PR from NIBP: Measurement 40-240bpm
- Over-pressure protection: Neonate: 150mmHg
Pediatric: 240mmHg

IBP
- Measurement Range: -30mmHg-300mmHg
- Channel: 2 channels
- Pressure names: ARP, PA, CVP, RAP, LAP,
ICP, P1,P2
- Accuracy: ±1% or ±1bpm, whichever is greater
- Calibration Mode: Zero Calibration
Dual TEMP
- Measurement range:0-50℃
- Resolution:0.1℃
- Accuracy:±0.1℃
- Measurement unit:℃/ºF

EtCO2—Sidestream/Mainstream (option)
- Method: Infrared Absorption Technique
- Sample Rate: 50mL/min, ±10mL/min (sidestream)
- CO2 Measurement Range: 0 to 150 mmHg
- CO2 Resolution: 0.1mmHg    0 to 69mmHg
0.25mmHg  70-150mmHg
- CO2 Accuracy: 0-40mmHg         ±2mmHg
41-70mmHg       ±5% of reading
71-100mmHg     ±8% of reading
101-150mmHg   ±10% of reading
- AwRR: ±1rpm
- Response time: <3 seconds, includes transport time,
- Risetime
- Calculation Method: BTPS (Body Temperature
Pressure Saturated)
- Sample Gas Flow rate: 50ml/min

Standard Configuration:
ECG, HR, Masimo SpO2, NIBP, RESP, 2 TEMP, PR

Options:
Nellcor SpO2,EtCO2,IBP,Thermal Recorder,Wireless Module