ICU Patient Monitor


Features:

● Unique design and parameter configuration as ICU monitoring Top-notch solution

● Ultra bright and vivid 12.1" TFT display
● Outstanding touch screen to simplify instant access
● Water-proof design on any challenged conditions
● Superior connectivity for network, data-sharing, software upgrade
● Our monitor mTouch8 could be used in HL7 system.


Technical Specification

Size and Weight
- Product size: 34.5x29.1x16.5cm
- Packing size: 44x41x40cm
- Net weight: 4.5kg
- Gross weight: 9kg

Display
- 12.1” color TFT Full Touch Screen
- Rolling and refreshing waveform display
- Resolution: 800×600

Multi displays
- Standard display
- Freeze display
- Large -font Display
- Trend coexist display
- Alarm limit display
- OxyCRG dynamic view display
- Bed-to-bed view display
- Multi-lead and ECG simultaneous display

Trace
- 12 waveforms
- Sweep Speed: 12.5mm/s, 25mm/s, 50mm/s

Indicator
- Power indicator light
- Battery indicator light

Inter Face
- Parameter cable inter face
- AC Power input socket
- Network inter face
- External VGA inter face for connection ofan
- Alternate Display

Battery
- Lithium-ion battery /Rechargeable
- Plug & Play battery, capacity:4000mA
- Maximum 12 hours for charging; 4 hours for
continuous working
- Electric specification: A.C220±22v, D.C 12V,
50Hz±1Hz
- Power: <70VA

Trend Time
- Trend graph: 120 Hours of trend graph storage recall
and print
- Data recall & print function: 200 groups parameter
alarm recall &print
200 groups Arrhythmia alarm recall &print
2000 groups NIBP recall & print
- Data power-off protection

Alarm
- User-adjustable High and Low limits audible and visual
alarm

Networking
- Connected to central monitoring system

Recorder
- Built-in, thermal array
- Waveform: 2 channels
- Record mode: manual, on alarm, time -defined, etc
- Paper width: 48mm
- Print speed:  25mm/s, 50mm/s

Record type:
- Consecutive real-time record, Automatic record,
Parameter alarm record, freeze Waveform record,
Review and Saving, Trend Review

Internal Modules
- Individual Modules
- ECG module, SpO2 module, NIBP module, Main
control module and Power supply module.

Operation Environment
- Power: AC100-250V, 50/60Hz.
- Temperature: 5-40℃
- Humidity: 15-85%
- Patient Range: Adult, Pediatric, Neonate

ECG
- 12-leads ECG Analysis
Heart Rate Range
Adult: 15-300bpm
Pediatric/Neonate:15-350bpm
Accuracy: ±1% or ±1 bpm (whichever is greater)
Resolution :1 bpm
-  ECG Enlarge width
MON: 0.5-40Hz
DIA: 0.05-130Hz
OPE: 1-20Hz
- Lead ion: 5 Lead and 3 lead able
5 lead: RA; LA; RL; LL; V or R; L; N; F; C
3 lead: RA; LA; LL or R; L; F
Lead ion: 12-Lead I; II; III; aVR; aVL;aVF; V1-V6.
5-lead: I; II; III; aVR; aVL
3-lead: I; II; III
ECG waveform: 2 channels
- ST SEGMENT detection: -2.0mV - +2.0Mv (Automatic)
- Arrhythmia analysis: Yes
- Electrode desquamated indicator: Voice & light indication
- Gain ion : ×1/4、×1/2 、×1、×2、Auto
- Sweep speed: 12.5mm/s, 25mm/s, 50mm/s
- HR alarming time: ≤ 12s
- PR from ECG
Adult: 15-300bpm
Pediatric/Neonate: 15-350bpm
- ECG noise level: ≤ 30 uV (P-P value)
- ECG input loop current: Ua
- Input impedance: 5 MΩ
- CMRR : ≥105 Db
- Time constant
Monitoring mode ≥0.3s
Diagnostics Mode≥3.2s
- Anti-jamming:  line frequency, electrosurgical interference
and defibrillation
- Arrhythmia Analysis and pacemaker detection
- ECG cable
Standard configuration ECG cable for Adult
Standard two ECG cables to support 12 leads ECG
analysis
- Alarm setting: Adjustable from lower to upper and
automatic memory
- Waveform: Standard 12-ECG waveforms

SINOHERO SpO2
- Measuring Range: 0 ~ 100 %
- Alarm Range: upper: 1 ~ 100 %   lower:0 ~ 99 %
- Error: 1%
- Resolution: 1%
- Accuracy: 1 %( 90% ~ 100%); 2% (70% ~ 90%); Pulse Rate
- Measuring and Alarm Range: 20~300bpm
- Accuracy: 1bpm

Masimo-SpO2
- Measurement Range:0% to 100%
- Resolution:1%
- Accuracy: 70% to 100%:±2%(adult/pediatric,non-motion
conditions)
70% to 100%:±3%(neonate,non-motion conditions)
70% to 100%:±3%(motion conditions)
0% to 69%, unspecified

PR
- Measurement Range:25bpm to 240bpm
- Accuracy: ±3bpm(non-motion conditions)
±5bpm(motion conditions)
- Resolution:1bpm

NIBP
- Measurement method: Automatic vibration
- Measurement types: Systolic, Diastolic, Mean
- Work mode: Manual / Automatic/Continuous
- Auto measurement time: Adjustable 1min-480min
- Measurement unit: mmHg / Kpa able
- Measurement range: 10-270mmHg
Adult/Pediatric Mode:
Systolic pressure                     60~240mmHg
Diastolic pressure 30-190mmHg
Mean pressure                        40-210mmHg
Neonatal Mode:
Systolic pressure                    25-135mmHg
Diastolic pressure                   12-110mmHg
Mean pressure                        18-120mmHg
- Alarm type: Systolic pressure, Diastolic pressure, Mean
pressure
- Accuracy:±5mmHg
- NIBP pressure range: 0-300 mmHg
- PR from NIBP: Measurement 40-240bpm
- Over-pressure protection :
Hardware and software both over pressure protection
300 mmHg is the max pressure.
Higher than the above pressure, the safety valve deflate
automatically

NIBP Cuff:
- Standard - Adult NIBP cuff ;
- Optional - Pediatric NIBP cuff , Neonatal NIBP cuff

Alarm Setting: Adjustable from lower to upper and automatic
memory

IBP
- Measurement Mode: Pressure Transducer
- Measurement Types: Systolic, Diastolic, Mean
- Channel: 2 channel
- Pressure names: AVP, CVP, PAR, LAP, RAP, ICP
- Measurement  Range: -30mmHg~300mmHg
- IBP Accuracy: 0~100mmHg  ±4mmHg
- 100mmHg~300mmHg  ±2%
- Pulse Accuracy: ±1% or ±1bpm, whichever is greater
- Calibration Mode: Zero Calibration
- Standard: US Abbott/Medex IBP accessories

Dual TEMP
- Measurement range: 0-50℃
- Channel: T1, T2, TD (Temperature Difference)
- Resolution: 0.1℃
- Accuracy: ±0.1℃(exclusive of error of sensor) - Measurement unit: ℃ / F able
- TEMP sensor: standard configuration- skin TEMP sensor
- Alarm setting: Adjustable from lower to upper and automatic
memory

RESP
- Method: R-F(RA-LL) impedance method
- RR measurement range
Adult: 7-120bpm
Neonate: 7-150bpm
- Resolution: ±1 rpm
- Accuracy: ±1rpm
- Alarm setting: Adjustable from lower to upper and automatic
memory
- ARR analysis, RESP Apnea Alarm:10s-40s

EtCO2
Sidestream (Microstream) CO2
- CO2 Measurement Range: 0 -150 mm Hg, 0 to 79%, 0 to
20kPa (at 760mmHg)
- Accuracy: ± 2 mm Hg (0 – 40 mm Hg)
± 5% of reading (41 – 70 mm Hg)
± 8% of reading (71 –100 mm Hg)
± 10% of reading (101 –150 mm Hg)
- Sampling Rate: 50ml/min. ±10ml/min
- Sampling rate accuracy: 15%
- Start-up time: <1 min, once the module starts up, it reaches
ISO accuracy
- Mode: 10 minutes after start-up, the module reaches full
accuracy mode
- Respiration rate: 0-120bpm
- Respiration rate accuracy: ±2rpm (0-70rpm)
±5rpm (>70rpm)
- Response time: <240msec (10% to 90%)
- Delay time: <2s
(Sampling line length: 7 inches; internal diameter: 0.055
inches; sampling gas flow rate: 150ml/min)

Mainstream CO2
- Method: Infrared Absorption
- Measuring mode: Mainstream
- Measurement range: 0 -150 mm Hg, 0 to 79%, 0 to 20kPa (at
760mmHg)
- Resolution: 0.1 mmHg 0 to 69 mmHg
0.25mmHg 70 to 150mmHg
- Accuracy: ± 2 mm Hg (0 – 40 mm Hg)
± 5% of reading (41 – 70 mm Hg)
± 8% of reading (71 –100 mm Hg)
± 10% of reading (101 –150 mm Hg)
- Alarm range: Same as Measurement range

BIS
- BIS measurement range and accuracy
- BIS: 0-100; accuracy: 1%.
- SQI: 0-100%; accuracy: 1%.
- EMG: 0~100dB; accuracy: 1%.
- ESR: 0~100%; accuracy: 1%.
- Alarm Limit: 0~100
- Step Size: 1

ICG
- ICG measurement method: Indirect impedance cardiography measurement
- Measurement range
- HR: 40~250bpm
- SV: 5~250mL
- C.O.:1.4~15L/min
- Measurement accuracy
- SV: not defined.
- HR: ±2bpm.
- C.O: no defined.
- Resolution
- SV: 0.1ml
- HR: 1bpm
- C.O: 0.1L/min
- Alarm Limit
- C.I.
- Upper limit: (lower limit + 0.1)~15.0L/min/m²
- Lower limit: 1.4~(upper limit - 0.1)L/min/m²
- Resolution: 0.1L/min/m²
- TFC
- Upper limit: (lower limit + 1)~150/KΩ
- Lower limit: 5~(upper limit - 1)KΩ
- Resolution: 1KΩ

CO
- More details please refer to CO specification

Multi Gas/AG
- More details please refer to AG Specification

Standard configuration of mTouch 8

Mainunit: 12.1” TFT-LCD Full Touch Screen, 3/5 Lead ECG, HR, Respiration,  Digital SpO2, NIBP, 2 TEMP, Lithium Battery, Handwriting Pen

Optional parameter& configuration of mTouch 8

2-IBP, EtCO2 (Sidestream (Microstream), Mainstream), Multigas/O2,12-Lead ECG, Masimo SpO2, Nellcor SpO2, CO, Thermal recorder, USB/SD Memory BIS, Wireless Module