Welcome to Sino-Hero(Shenzhen)Bio-Medical Electronics Co.,Ltd
mTouch9
Catalog Download
Product Introduction

ICU/CCU Patient Monitor

Features:

●15" TFT full touch screen with ultra view
●Slim design ensuring performance with style
●External 4-channel wide-size printer, stand by any time
●Bulk-capacity SD card and USB Flash Disk to ensure unlimited data storage
●High-end parameters for option: 12-lead ECG, Maximo SpO2, AG. CO etc.
●Wire or wireless networking available


Technical Specification


Size and Weight
- Product size: 36x32.4x12cm
- Packing size: 46x32x43cm
- Net weight: 4.7kg
- Gross weight: 8kg

Display
- 15” color TFT Full Touch Screen
- Resolution: 1024×768

Multi displays
- Standard display
- Large-font display
- Short Trend display
- OxyCRG display

Indicator
- Power indicator light
- Battery indicator light

Interface
- Parameter cable interface
- AC Power input socket
- Ground wire interface
- Network interface
- Alternate Display
- USB interface
- SD memory card interface
- 7 waveforms on the screen

Battery
- Li-ion battery /Rechargeable
- 5 hours for charging; 4 hours for continuous working

Trend Graph
- Reviewable Parameters: HR,ST,SpO2,PR,NIBP,RR,TEMP
- Resolution: 1s, 5s, 5min, 10min

Trend Table
Reviewable Parameters: HR,ST,SpO2,PR,NIBP,RR,T1,T2,TD
Resolution: 1, 5, 10, 30,60min
Trend Data: 256 Hours trend data for all parameters
NIBP measurement: 400 Groups

Alarm
- Categories: Physical alarms and Technical alarms
- Priority: High, Medium and Low
- Alarm sound levels: 0,1,2,3,4
- Notification: Visual and Audible

Networking
- Connected to central monitoring system

Recorder
- Type: Thermal dot array
- Number of waveform channels: 3 (standard), 4(optional)
- Paper width: 112mm
- Paper length: 20m
- Print speed: 25mm/s other speeds can be defined (optional)

Operation Environment
- Temperature: 0℃-40℃
- Relative humidity: ≤85% (noncondensing)
- Atmospheric pressure: 860hpa-1060hpa
- Patient Range: Adult, Pediatric, Neonate

ECG
- Lead Mode: 3-lead , 5-lead
- Lead ion: I,II, III / I,II,III,V,AVR,AVL,AVF
- Gain: ×0.25,×0.5,×1,×2,Auto
- Sweep speed: 12.5mm/s, 25mm/s, 50mm/s
- Multi-lead display: 6 waveforms
- Alarms: User-able upper and lower heart rate limits

HR
- Heart Rate for Adult: 15-300bpm
- Heart Rate for Neonate/Pediatric: 15-350bpm
- Heart Rate Accuracy: ±1bpm or ±1%, whichever is greater
- Heart Rate Resolution: 1bpm
- Notch: 50Hz, 60Hz

ST Segment
- ST segment range:  -2.0mv to 2.0mv
- ST alarm range: -2.0mv to 2.0mv
- ST segment accuracy: -0.8mv to 0.8mv
- ST segment error: ±0.02mv
- Arrhythmia type: 13 types

SpO2
- Measurement range: 0%~100%
- Resolution: 1%
- Accuracy: ±2%(70%-100%); unspecified(0-69%)
- Alarm range: 0~100%

Pulse Rate
- Measurement range: 20bpm~300bpm
- Resolution: 1bpm
- Accuracy: ±1bpm
- Alarm range: 0~254bpm


NIBP
- Measurement technique: Oscillometric
- Measurement types: Systolic, Diastolic, Mean
- Work mode: Manual, Auto, STAT
- Auto measurement time: 0-4 hours
- Measurement unit: mmHg / Kpa able
- Measurement range:
Adult Mode:                      Systolic pressure                      40~270mmHg
Diastolic pressure                     10-215mmHg
Mean pressure                          20-235mmHg
Pediatric Mode:                Systolic pressure                       40~200mmHg
Diastolic pressure                     10-150mmHg
Mean pressure                          20-165mmHg
Neonatal Mode:                Systolic pressure                      40-135mmHg
Diastolic pressure                     10-100mmHg
Mean pressure                          20-110mmHg
- Accuracy:  5%
- Resolution: 1mmHg
- Alarms : Selectable upper and lower limits for systolic, diastolic and mean pressure
- Over-pressure protection: Double safety protection

IBP
- Channels: 1 or 2, 4 able
- Measurement Mode: Pressure Transducer
- Measurement  Range: -60mmHg~300mmHg
- Accuracy: ±1mmHg or ±2%, whichever is greater(without sensor)
- Pressure name: ART, PA, CVP, RAP, LAP, ICP, P1, P2
- Alarm range: -10~300mmHg

TEMP
- Measurement unit: ºCelsius(℃) or ºFahrenheit(F)
- Measurement range: 0-50℃
- Channel: T1, T2, TD (Temperature Difference)
- Resolution: 0.1℃
- Accuracy: ±0.1℃
- Probe type: YSI type

RESP
- Measurement technique: RA-LL Impedance variation detection
- Range:   Adult:  7~120rpm
Pediatric/Neonate: 7~150rpm
- Apnea alarm: 10s,15s,20s,25s,30s,35s,40s able
- Sweep speed: 6.25mm/s, 12.5mm/s, 25mm/s
- Gain: 0.25, 0.5, 1, 2, 4

EtCO2
Mainstream CO2
- Measurement Range: 0 -150 mm Hg
- Accuracy: ± 2 mm Hg (0 – 40 mm Hg)
± 5% of reading (41 – 70 mm Hg)
± 8% of reading (71 –100 mm Hg)
± 10% of reading (101 –150 mm Hg)
- RR range: 0 to 150rpm
- Accuracy: 1rpm
- Response time: <60ms

Sidestream CO2
- Measurement range: 0 -150 mm Hg
- Accuracy: ± 2 mm Hg (0 – 40 mm Hg)
± 5% of reading (41 – 70 mm Hg)
± 8% of reading (71 –100 mm Hg)
± 10% of reading (101 –150 mm Hg)
- Sample flow rate: 50ml/min
- Accuracy: ±15% or 15ml/min,whichever is greater
- Warm-up time: <1min,enter the iso accuracy mode
After 1 min,enter the full accuracy mode
- RR range: 0-120rpm
- RR accuracy: ±2 rpm

Multi Gas
- Measure method: Infrared spectrum
- Fi and ET values: CO2 ,N2O ,O2 ,AG(HAL,ISO,NEF,SEV,DES)
- Resolution:1%
- Unit:%
- Calibration: Room air calibration automatically when changing airway
Adapter (<5 sec)
- Warm-up time:<10S,full accuracy within 1min
- Measurement and alarm range of AG
- Gas                      Range             Accuracy
CO2                     0-10%            ±(0.3% ABS+4%REL)
N2O                     0-100%          ±(2% ABS+8%REL)
O2                       10-100%         ±(2% ABS+2%REL)
HAL,ISO,ENF      0-5%              ±(0.15% ABS+10%REL)
SEV                     0-8%              ±(0.15% ABS+10%REL)
DES                     0-18%            ±(0.15% ABS+10%REL)
- awRR measurement range:  0~150rpm
- awRR measurement Accuracy: ±1rpm
- Rise time(flowing speed 10I/min)CO2≦90ms
O2≦300ms
N2O≦300ms
Hal,Iso,Enf,Sev,Des≦300ms
- Total system response time :<1seconds

Standard Configuration of mTouch 9
15” TFT-LCD Full Touch Screen, 3/5 Lead ECG, PR/HR, RESP, SpO2, NIBP, TEMP, Li-ion Battery

Optional configuration of mTouch 9
Masimo SpO2, 2-IBP, EtCO2 (Sidestream, Mainstream),12-Lead ECG
Multigas,VGA,C.O,Printer