Welcome to Sino-Hero(Shenzhen)Bio-Medical Electronics Co.,Ltd
Me
Catalog Download
Product Introduction

Transport Monitor


NEW Features:

Innovative Stand design working with EMS to deliver best care in any challenging, fast-paced environment
Compact monitor with 3.5" Full-touch TFT-LCD display and automatic re-orientation feature
Ergonomic handle with 12V DC power for fast ER and transport monitoring
Various parameter configurations enable continuous multi-functional patient monitoring
Lasting more than 60 minutes as independent monitor with built-in rechargeable Li-ion battery


Size and Weight
- Size:160mmx99mmx71mm
- Weight: < 1.2kg

Power supply
- Power Voltage: AC 100-240V 50/60Hz
- Safety class: Category I
- 12V DC input

Display
- 3.5" Color Anti-glare Full-touchTFT-LCD
- Resolution:320x240pixels
- Built-in Gravity sensor

Battery
- Type: Rechargeable Lithium battery,3.7V/1800mAH
- Operating time under the normal use and full charge: >60minutes

Alarm
- Level: Low, medium and high
- Indication: Auditory and visual
- Patient Physiological Alarm Light color: Yellow & Red
- Equipment Technical Alarm Light color: Blue

Input device
- Touch screen: Standard configuration
- Shortcut Keys: 5

Trend & Reviewing
- Trend:8 hours power-off storage
- NIBP measurement reviewing:400 groups

Environment
- Operating temperature: +5℃ to +40℃
- Storage temperature: -20℃ to +50℃
- Operating humisity: 15% to 85% (non condensing)
- Storage humidity: 10% to 93% (non condensing)
- Operating atmospheric pressure: 860hPa to 1060hPa
- Storage atmospheric pressure: 500hPa to 1060hPa

ECG
- Lead Mode: 3-leads ECG input
5-leads ECG input
12-leads ECG input
- Lead ion: Ⅰ,Ⅱ,Ⅲ,
Ⅰ,Ⅱ,Ⅲ,aVR,aVL,aVF,V-
Ⅰ,Ⅱ,Ⅲ, aVR,aVL,aVF,V1~V6(option)
- Gain: 1.25mm/mV(x0.125)2.5mm/mV(x0.25), 5mm/mV(x0.5), 10mm/mV(x1), 20mm/mV(x2), Auto
- CMRR: Monitor mode≧105dB
Surgery mode≦105dB
Diagnostic mode≧90dB
- Frequency response(-3d B):
Monitor mode 0.5~40Hz
Surgery mode 1~25Hz
Diagnostic mode 0.05~150Hz
- Input impedance: ≧5.0Mohm
- ECG signal range:±10.0mV
- Electrode offset potential: ±500mV
- Patient Leakage Current:<10uA
- Standardizing signal:1mV±5%
- Baseline recovery: <3s after Defibrillation (Monitor mode)
<1s after Defibrillation (Surgery mode)
- Indication of electrode separation: Every electrode(exclusive of RL)
- Protection: Breakdown Voltage 4000AVC 50/60Hz;defibrillator proof
- Sweep speed:12.5mm/s,25mm/s,50mm/s

HR
- Range: Adult 10~300bpm
Pediatric & Neonate: 10~350bpm
- Resolution: 1bpm
- Accuracy: ±1% or ±1bpm,whichever is greater

ST segment
- Measurement range:-2.0mV-2.0mV
- Accuracy: -0.8mV-0.8mV: ±0.02mV or ±10% whichever is greater Over ±0.8mV: unspecified
- Resolution:0.01mV

RESP
- Method: Thoracic impedance
- Lead Selected from: Ⅰ(RA-LA)orⅡ(RA-LL);Default: Ⅱ
- Gain: x0.25, x1, x2, x4
- Bandwidth:0.25Hz to 2.0Hz (-3dB)
- Sweep Speed: 6.25mm/s,12.5mm/s,25mm/s
- Measurement Range:0~150 rpm
- Resolution: 1rpm
- Accuracy: ±2rpm or 2% whichever is greater
- Delay of Apnea Alarm: off,  10s,15s,25s,30s,35s,40s,45s,50s,55s,60s

NIBP
- Way of measurement: Automatic oscillometr
- Range of measurement:
Adult: SYS 30~270mmHg
DIA 10~220mmHg
MAP 20~235mmHg

Child: SYS 30~235mmHg
DIA 10~220mmHg
MAP 20~225mmHg

Neonate: SYS 30~135mmHg
DIA 10~100mmHg
MAP 20~125mmHg

- Cuff pressure range: 0~300mmHg
- Resolution:1mmHg
- Pressure Accuracy: Static:±2% or ±3mmHg,whichever is greater
Clinical: ±5mmHg average error
Standard deviation:<8mmHg
- Unit mmHg, kPa
- Measurement mode: Manual, Auto, STAT
- Intervals for AUTO measurement time:1,2,3,4,5,10,15,30,60,90 minutes;
2,4,8,12 hours
- STAT mode cycle time: keep 5 minutes, at 5 seconds interval.
- Overpressure Protection: Hardware and software double protections
- Pulse rate range:40~240bpm

Digital SpO2
- Measurement Range:0~100%
- Resolution:1%
- Accuracy: At70~100%,±2%
At0~69%,unspecified

PR
- Measurement Range:25~255bpm
- Resolution:1bpm
- Accuracy: ±1% or ±1 bpm,whichever is greater

Nellcor SpO2
- Measurement Range:0~100%
- Resolution:1%
- Accuracy:At70~100%:±2%(Adult)
At70~100%:±3%(Neonate)
At70~100%:±2%(Low Perfusion)
At0~69%,unspecified

PR
- Measurement Range:20~300bpm
- Resolution:1bpm
- Accuracy: 20bpm to 250bpm: ±3bpm
251bpm to 300bpm: unspecified

Masimo SpO2
- Measurement Range:0% to 100%
- Resolution:1%
- Accuracy: 70% to 100%: ±2% (adult/pediatiic, non-motion conditions)
70% to 100%: ±3% (neonate, non-motion conditions)
70% to 100%: ±3% (motion conditions)
0% to 69%, unspecified
- Average time: 2-4s,4-6s,8s,10s,12s,14s,16s

PR
- Measurement Range:25bpm to 240bpm
- Accuracy: ±3bpm(non-motion conditions)
±5bpm(motion conditions)
- Resolution:1bpm

TEMP
- Measurement way: Thermal resistance
- Measurement Range: 0.0℃ —50.0℃ (32℉~122℉)
- Accuracy: ±0.1℃ or ±1℃ (exclusive of probe)
- Resolution: 0.1℃ or 1℉
- Unit: Celsius(℃),Fahrenheit(℉)

IBP
- Max Channel: 2
- Measurement way: Directly invasive pressure measurement
- Sensitivity of transducer: 5uVM mmHg
- Impedance of transducer: ±2%, 300 to 3000Ω
- Measurement Range: -50 to +350mmHg
- Resolution: 1mmHg
- Unit mmHg, kpa, cmH2O
- Accuracy:
Static: ±1mmHg or ±2%, whichever is grater(exclusW of transducer)
±4mmHg or ±4%, whichever is grater(inclusion of transducer)
Dynamic: ±4mmHg or 4%, whichever is grater
Transducer sites: Arterial Pressure (ART)
Pulmonary Artery Pressure (PA)
Left Atrium Pressure (LAP)
Right Atrium Pressure (RAP)
Central Venous Pressure (CVP)
Intracranial Pressure (ICP)

- Selection of measurement range:
ART: 0~+350mmHg
PA: -10~+120mmHg
CVP/RAP/LAP/ICP: -10~+40mmHg


Standard configuration of Me:


3/5 Lead ECG, SpO2, RESP, HR/PR, 2-TEMP, Rechargeable Lithium Battery


Optional configuration of Me:

Nellcor SpO2, Masimo SpO2, 2-IBP, 12 Lead ECG, EMS Charging Stand