Welcome to Sino-Hero(Shenzhen)Bio-Medical Electronics Co.,Ltd
iS12
Catalog Download
Product Introduction

Modular Patient Monitor


Features:

Combination of High Technology & Elegant Design

12.1" Low Power Consumption Full Touch LED Screen
Flexibility and Freedom to Re-configure Major Monitoring Parameters
Exceptional Connectivity by High-speed Wire or Wireless Networking

NO FAN Ultra Quiet Design Suitable for Critical Requirement


Technical Specification

Safety

IEC60601-approved
Dimension and Weight
Product size: 31.5x27.2x12.1cm
Packing size: 42x30x35cm
Net weight: 4.3kg
Gross weight: 9kg

Operation Environment
Power Requirement: AC100-240V, 50/60Hz,140VA,1.4A-0.59A
Temperature: 0℃-40℃
Humidity:15%-80% (non-condensing)
Patient range: Neonate, pediatric and adult patient
Display: 12.1" Color TFT LCD with LED background
800*600 Resolution Multi displays able, including
Standard display
Trend coexist display
Large-font display
OxyCRG dynamic view display
Night mode
Trace:7 traces
Sweep speed:12.5mm/s,25mm/s,50mm/s
Indicator: Alarm indicator light
Power indicator light
Battery indicator light
QRS beep and alarm sound

Li-ion Battery
Rechargeable
One battery about 270 minutes for continuous working


Alarm and Indicator
User-adjustable High, Medium, and Low
limits 3-level audible and visual alarm
Alarm indicator light
Power indicator light
Battery indicator light
QRS beep and alarm sound
Pulse rate modulation sound

Networking
Wire or wireless connected to central station system

Recorder
Thermal printer Real time recording
Paper width: 50mm
Waveform: 2 Channel (standard)
Print speed: 25mm/s

ECG
Input:3-Lead or 5-Lead able
3 Lead cable: RA, LA, LL or R, L, F
5 Lead cable: RA, LA, RL, LL, V or R, L, N, F, C
Lead ion: 3-lead: 1,11,111 5 Lead: I, II, Ill, AVR, AVL, AVF, V
ECG Waveform:2 Channel
Gain ion: x0.25,x0.5,x1,x2,x4
Sweep speed: Auto 12.5mm/s, 25mm/s, 50mm/s
Heart Rate:for Neonate 15-350BPM
Heart Rate: for Adult/Pediatric 15-300BPM
Accuracy:lbpm or 1%, whichever is greater
Resolution: 1 bpm
Filter Diagnostic mode: 0.05-100Hz
Monitor mode: 0.5-40Hz
Surgical mode: 1.0-25Hz
Protection: Withstand 4000VAC/50Hz Voltage in isolation
Against electrosurgical interference and defibrillation
Alarm range: Neonate: 15-350BPM
Adult/Pediatric: 15-300BPM
ST segment detection: Measurement range: -2.0mv to 2.0mv
Alarm range: -2.0mv to 2.0mv
Arrythmia analysis: Yes
Alarm: Audible and visual alarm, alarm event recallable
Pace detection: Yes
Drug dose calculation: Yes
Standby mode: Yes

Respiration
Method: Thoracic impedance
Measurement range: Neonate/Pediatric: 0-150RPM Adult: 0-120RPM
Apnea alarm: No alarm,10s,15s20s, 25s,30s,35s, 40s able
Alarm: Audible and visual alarm, alarm events recallable

NIBP
Method: Oscillometric
Measurement modes: Manual/Automatic/Continuous
Displayed parameters: Systolic diastolic and MAP (mean arterial pressure)
Auto measure time: Adjustable
Measurement unit:mmHg/kPa able
Measurement type: Systolic, Diastolic, Mean
Range of Systolic Pressure: Adult: 40-270mmHg
Pediatric: 40-200mmHg
Neonate: 40-135mmHg
Range of Diastolic pressure:Adult: 10-210mmHg
Pediatric: 10-150mmHg
Neonate: 10-100mmHg
Range of Mean pressure: Adult: 20-230mmHg
Pediatric: 20-165mmH
Neonate: 20-110mmHg
Accuracy: ±6mmHg
Resolution: 1mmHg
Alarm: Systolic, Diastolic, Mean
Over-pressure protection: Double safety protection

IBP
Channel 1 or 2 able
Measurement range: -50-400mmHg
Resolution: 1mmHg
Alarm Systolic, Diastolic, Mean

SpO2
Measurement range: 0%-100%
Resolution:1%
Accuracy:±2%(70%-100%); unspecified(0-69%)
Alarm range: 0-100%
Pulse Rate Range: 20-254bpm
Resolution: 1bpm
Accuracy:±3bpm
Alarm range: 0-254bpm

Temperature
Measurement range: 0-50℃
Resolution: 0.1℃
Accuracy: ±0.1℃
Channel: T1, T2, TD

EtCO2
Mainstream CO2
Measurement Range: 0 -150 mm Hg
Accuracy: ± 2 mm Hg (0 – 40 mm Hg)
± 5% of reading (41 – 70 mm Hg)
± 8% of reading (71 –100 mm Hg)
± 10% of reading (101 –150 mm Hg)
RR range: 0 to 150rpm
Accuracy: 1rpm
Response time: <60ms

Sidestream CO2
Measurement range: 0 -150 mm Hg
Accuracy: ± 2 mm Hg (0 – 40 mm Hg)
± 5% of reading (41 – 70 mm Hg)
± 8% of reading (71 –100 mm Hg)
± 10% of reading (101 –150 mm Hg)
Sample flow rate: 50ml/min
Accuracy: ±15% or 15ml/min,whichever is greater
Warm-up time: <1min,enter the iso accuracy mode
After 1 min,enter the full accuracy mode
RR range: 0-120rpm
RR accuracy: ±2 rpm

Multi-gas/AG
Method: Infrared Absorption
Gas accuracy:
CO2:0 to 15vol%,±(0.2vol%+2% of reading) 15 to 25vol%, Unspecified
N2O:0-100vol%,±(2vol%+2% of reading)
ENF,lSO,HAL:0-8vol%,±(0.15vol%+5% of reading) 8 to 25vol%, Unspecified
Data output: Fi and Etvalues
Respiration Rate:0 to 150±1RPM
Other: Agent mixture detection and MAC value displayed

Interfacing
1 AC power connector
1 RJ45 network connector
2 USB 2.0 connector
1 VGA output connector
1 Multifunction output connector
1 Nurse call
1 ECG Analog output

Data Storage
Trend date: 168 hours
Alarm events: 100 events
NIBP: 1600 recall
Waveforms: Max. 4 hours
Trend table/Trend graph: 1000 hours

Copyright 2017 Sino-Hero(Shenzhen)Bio-Medical Electronics Co.,Ltd. 粤ICP备06126166号